This independent 3D reconstruction of the HI-STORM 100S system is a technical study based on publicly available sectional drawings, dimensional data, technical descriptions and information on materials. The spatial model brings these data together in a single assembly, allowing the relative positions of components and the internal geometric consistency of the reconstruction to be checked. The available documentation and selected system variant define the scope of the reconstruction.
This article examines the reconstruction process. The purpose and operation of the technology are covered in the separate article Dry Storage of Spent Nuclear Fuel.

Documentation as the Basis for the Model
The primary documentary basis is the Final Safety Analysis Report (FSAR) for the HI-STORM 100 system. Sectional drawings establish the arrangement of components, dimensional data define their size and position, and technical descriptions explain relationships that are not apparent from an individual drawing. Material tables help identify components but do not replace information on their geometry.
Directly documented geometry comprises features unambiguously defined by dimensions and labels on a drawing. Other spatial relationships must be established by comparing several views: a longitudinal section may define a component’s height, a transverse section its arrangement, and a description the assembly to which it belongs. This interpretation remains constrained by the source data. A missing detail cannot be substantiated solely because it appears to fit the model.
Document revisions also form part of the checking process. The FSAR states that drawings have their own revision identifiers and that the revision of a bill of materials does not necessarily match that of the corresponding drawing. Matching data by component name alone is therefore insufficient; the system variant and documentation basis must also be consistent.
The Fuel Basket as the Starting Point for the Internal Geometry
The fuel basket provided the geometric starting point for the reconstruction. Its cell arrangement determines the relationships between fuel assembly positions, cell walls, neutron absorbers and the basket’s overall envelope. That envelope must be compatible with the documented internal space of the MPC (Multi-Purpose Canister).

The basket dimensions do not, by themselves, determine the dimensions of the canister. The MPC’s internal diameter, shell thickness and height impose additional constraints against which fit and clearances are checked. In the reconstruction, the basket is modelled separately from the canister enclosure, although it is functionally part of the MPC assembly. The canister’s construction description identifies the cylindrical shell, baseplate, lid, port cover plates and closure ring as components of the welded assembly.
Distinguishing between these components prevents the MPC closure from being confused with the overpack lid. Their positions are checked against different mating surfaces and the corresponding dimensions.
Assembling the Overpack Geometry
In section, the components are arranged from the inside out as follows:
fuel basket → MPC shell → air space → overpack inner shell → concrete fill → outer shell.
Concrete fills the region between the two steel shells. The air space extends between the outer surface of the MPC and the inner surface of the overpack and connects to the ventilation ducts. It remains outside the sealed canister.
This breakdown allows radial relationships to be checked. With an idealised coaxial arrangement, the radial clearance can be estimated as half the difference between the overpack’s internal diameter and the MPC’s external diameter. Supports or other structural elements may locally reduce the actual free space. The external silhouette alone is therefore insufficient to assess geometric consistency.
A longitudinal section allows vertical relationships to be checked separately. The height of the MPC must be considered in relation to its support surface, the internal cavity and the lower boundary of the upper assembly. Individual dimensions must use compatible reference planes. The overall height of the overpack does not, by itself, define the usable internal height.
Caption for the upper overpack detail: Upper part of the overpack shown without its lid. The line rendering reveals the relationship between the inner and outer shells and the arrangement of structural elements along the upper rim.
Distinguishing Between System Variants
HI-STORM 100, HI-STORM 100S and HI-STORM 100S Version B belong to the same system family, but differ in specific geometric and structural details. Comparative drawings identify differences in overpack height, MPC support and the arrangement of ventilation ducts.
In HI-STORM 100, the outlet ducts are located in the overpack body and are vertically aligned with the inlet ducts. In HI-STORM 100S and Version B, they form part of the lid assembly and are not vertically aligned with the inlets. The reconstruction must therefore also account for the circumferential positions of the openings, which a single longitudinal section cannot fully describe.
Version B also differs in its lower region: the documented MPC support assembly does not have the concrete-filled pedestal used in the 100 and 100S variants. The MPC is supported by a steel plate. Transferring height data from another variant could therefore place the MPC incorrectly relative to the air inlets and upper assembly.
These differences constrain the use of reference drawings. An assembly combining geometric elements from different variants may appear plausible without corresponding to any documented system configuration.
Reconstructing the Overpack Lid
The overpack lid required the most extensive cross-referencing of information. A simplified section establishes its approximate outline and position, but does not necessarily resolve the interfaces between the shielding section, steel components, fasteners and ventilation ducts.
In the reconstruction, I represented these components separately, including the threaded studs, nuts and mesh screens. Their positions must be consistent with both the overpack body and the airflow path. For the 100S variant, this means checking the connection between the annular space around the MPC and the ducts within the lid. The arrangement of shielding material, plates and fasteners must remain consistent with the documented airflow path through the upper assembly.
Component names must be checked against the corresponding parts. Table 2.2-3 in Holtec’s documentation distinguishes between Top Plate and Lid Top Plate and identifies the variants to which each component applies. In that table, Heat Shield and Heat Shield Ring apply to HI-STORM 100; their appearance in documentation for the HI-STORM 100 family does not justify including them in a reconstruction of 100S.
Similarity between two drawings therefore does not establish that their designs are identical. The assembly to which each part belongs, its interfaces and the duct locations must be compared. A component table can confirm a part’s identity, but cannot define its detailed geometry without an appropriate drawing.
Materials and Visual Representation
Material identity is determined by the technical information for the selected component and system variant. BORAL and METAMIC are different neutron absorber materials, whose use depends on the documented system configuration.
I used colour to distinguish components: carbon steel is dark blue-grey, stainless steel is silver, concrete is light grey, fasteners are dark, and absorber plates are highlighted separately. These colours are a visual convention. They do not establish material specifications, safety classification or actual surface appearance.
Consistent visual treatment of the same component across different views allows its geometry to be followed. A sectional view reveals hidden relationships; rendering makes them visually legible.
Checking Spatial Consistency

The assembled model allows information from several views to be checked for geometric consistency. A component may agree with one drawing yet cause an overlap, an incompatible vertical position or a discontinuity in the airflow path when incorporated into the complete assembly.
If such an inconsistency occurs, the source dimension, reference plane, interpretation of the sectional drawing and selected variant must be checked again. Geometry cannot be adjusted simply to make the assembly fit. If the public sources do not resolve the relationship, the detail remains unconfirmed.
These checks concern the internal consistency of the reconstruction in relation to the sources used. They do not validate the original design. Even a geometrically consistent assembly may contain simplifications arising from the limited scope of the documentation.
Scope and Limitations of the Model
The reconstruction is not a validated computational model for thermal, criticality, mechanical or structural analyses. Nor does it constitute a radiological or shielding analysis. Sectional views and renders show spatial relationships; they do not, by themselves, demonstrate compliance with safety criteria.
This is an independent reconstruction developed as a technical study using publicly available documentation. The model and visualisations are original work by Elite Studio 3D, intended for education and technical communication. They are not an official model from Holtec International and do not constitute licensing, design or operating documentation.
References
Holtec International. HI-STORM 100 System Final Safety Analysis Report. HI-2002444, Revision 4, 10 April 2006. In particular, Chapter 1 and the associated drawings and component data. NRC ADAMS ML063240599.
Chopra, O. K., Diercks, D., Fabian, R., Ma, D., Shah, V., Tam, S.-W., and Liu, Y. Y. Managing Aging Effects on Dry Cask Storage Systems for Extended Long-Term Storage and Transportation of Used Fuel. Revision 0, ANL-12/29, FCRD-USED-2012-000119. Argonne National Laboratory, prepared for the U.S. Department of Energy, 30 June 2012. Chapter V.2, particularly Sections V.2.1.1 and V.2.1.2 and Figures V.2-1, V.2-2 and V.2-11.
Holtec International. Certificate of Compliance Renewal Application for the HI-STORM 100 Dry Storage System. HI-2188877, Revision 0. Certificate of Compliance No. 1014, Docket No. 72-1014. In particular, the glossary, overpack description and Table 2.2-3, pp. 2-10–2-12.
Holtec International. Multi-Purpose Canisters. Official technical description of MPC construction.
3D Reconstruction criticality control Decay Heat Dry Storage FSAR HI-STORM 100S MPC Nuclear Communication Passive Cooling shielding Spent Nuclear Fuel technical reconstruction.
Last modified: October 28, 2026